DC/DC Railway Converter
•
•
•
Compact SIP-8 metal case
•
•
•
I/O-isolation 3‘000 VDC
•
Short circuit protection and current
limitation
•
•
Remote On/Off
TMR 6WIR Series, 6 Watt
EN 50155 railway approval
Ultra wide 4:1 Input: 9–36, 18–75 and
43–160 VDC
Fully regulated outputs
UL 62368-1 IEC 62368-1
Operating temperature range –40°C to
+80°C
3-year product warranty
The TMR 6WIR series is a set of 6 Watt DC/DC converters in a SIP-8 metal
case. They operate up to 60°C environment temperature at full load and up to
80°C with a 50% load derating. With EN 50155 and UL 60950-1 certification,
3’000 VDC I/O-isolation voltage, external On/Off, current limitation and short
circuit protection they cover a wide range of application when space is limited.
The input of the converters is designed for a wide voltage range (4:1) and minimum load is not required.
Models
Order Code
Input Voltage
Range
TMR 6-2410WIR
TMR 6-2411WIR
TMR 6-2419WIR
TMR 6-2412WIR
TMR 6-2413WIR
TMR 6-2415WIR
TMR 6-2421WIR
TMR 6-2422WIR
TMR 6-2423WIR
TMR 6-4810WIR
TMR 6-4811WIR
TMR 6-4819WIR
TMR 6-4812WIR
TMR 6-4813WIR
TMR 6-4815WIR
TMR 6-4821WIR
TMR 6-4822WIR
TMR 6-4823WIR
TMR 6-7210WIR
TMR 6-7211WIR
TMR 6-7219WIR
TMR 6-7212WIR
TMR 6-7213WIR
TMR 6-7215WIR
TMR 6-7221WIR
TMR 6-7222WIR
TMR 6-7223WIR
www.tracopower.com
9 - 36 VDC
(24 VDC nom.)
18 - 75 VDC
(48 VDC nom.)
43 - 160 VDC
(110 VDC nom.)
Output 1
Output 2
Vnom
Imax
3.3 VDC
5 VDC
9 VDC
12 VDC
15 VDC
24 VDC
+5 VDC
+12 VDC
+15 VDC
3.3 VDC
5 VDC
9 VDC
12 VDC
15 VDC
24 VDC
+5 VDC
+12 VDC
+15 VDC
3.3 VDC
5 VDC
9 VDC
12 VDC
15 VDC
24 VDC
+5 VDC
+12 VDC
+15 VDC
1'500 mA
1'200 mA
666 mA
500 mA
400 mA
250 mA
600 mA
250 mA
200 mA
1'500 mA
1'200 mA
666 mA
500 mA
400 mA
250 mA
600 mA
250 mA
200 mA
1'500 mA
1'200 mA
666 mA
500 mA
400 mA
250 mA
600 mA
250 mA
200 mA
September 28, 2023
Vnom
Efficiency
Imax
–5 VDC
–12 VDC
–15 VDC
600 mA
250 mA
200 mA
–5 VDC
–12 VDC
–15 VDC
600 mA
250 mA
200 mA
–5 VDC
–12 VDC
–15 VDC
600 mA
250 mA
200 mA
typ.
81 %
84 %
86 %
87 %
88 %
87 %
84 %
87 %
87 %
81 %
84 %
85 %
87 %
87 %
87 %
84 %
87 %
87 %
80 %
83 %
85 %
86 %
86 %
86 %
83 %
86 %
86 %
Page 1 / 4
TMR 6WIR Series, 6 Watt
Input Specifications
Input Current
- At no load
24 Vin models:
48 Vin models:
110 Vin models:
24 Vin models:
48 Vin models:
110 Vin models:
24 Vin models:
48 Vin models:
110 Vin models:
Surge Voltage
Recommended Input Fuse
Input Filter
6 mA typ.
6 mA typ.
2 mA typ.
50 VDC max. (1 s max.)
100 VDC max. (1 s max.)
185 VDC max. (1 s max.)
1'250 mA (slow blow)
630 mA (slow blow)
315 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Internal Capacitor
Output Specifications
Voltage Set Accuracy
Regulation
- Input Variation (Vmin - Vmax)
- Load Variation (0 - 100%)
Ripple and Noise
- Cross Regulation
(25% / 100% asym. load)
- 20 MHz Bandwidth
Capacitive Load
- single output
±1% max.
0.2% max.
0.2% max.
0.5% max.
1% max. (Output 1)
1% max. (Output 2)
dual output models: 5% max.
single output models:
dual output models:
single output models:
dual output models:
3.3 Vout models:
5 Vout models:
9 Vout models:
12 Vout models:
15 Vout models:
24 Vout models:
5 / -5 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
- dual output
Minimum Load
Temperature Coefficient
Hold-up Time
Start-up Time
Short Circuit Protection
Output Current Limitation
Transient Response
- Response Time
50 mVp-p typ.
75 mVp-p max.
2'200 µF max.
1'100 µF max.
680 µF max.
470 µF max.
470 µF max.
180 µF max.
680 / 680 µF max.
330 / 330 µF max.
180 / 180 µF max.
Not required
±0.02 %/K max.
10 ms min. (acc. to EN 50155 Class S2, see
application note for ext. capacitor calculation:
www.tracopower.com/info/holdup_en50155.pdf)
50 ms typ. / 75 ms max.
Continuous, Automatic recovery
180% typ. of Iout max.
250 µs typ. (25% Load Step)
Safety Specifications
Standards
- IT / Multimedia Equipment
- Railway Applications
- Certification Documents
EN 62368-1
IEC 62368-1
UL 62368-1
EN 50155
www.tracopower.com/overview/tmr6wir
Pollution Degree
PD 2
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 28, 2023
Page 2 / 4
TMR 6WIR Series, 6 Watt
EMC Specifications
EMI Emissions
EN 50121-3-2 (EMC for Rolling Stock)
EN 55011 class A (with external filter)
EN 55011 class B (with external filter)
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
EN 55011 class A (with external filter)
EN 55011 class B (with external filter)
EN 55032 class A (with external filter)
EN 55032 class B (with external filter)
- Conducted Emissions
- Radiated Emissions
EMS Immunity
- Electrostatic Discharge
- RF Electromagnetic Field
- EFT (Burst) / Surge
- Conducted RF Disturbances
- PF Magnetic Field
External filter proposal: www.tracopower.com/overview/tmr6wir
EN 50121-3-2 (EMC for Rolling Stock)
Air: EN 61000-4-2, ±8 kV, perf. criteria A
Contact: EN 61000-4-2, ±6 kV, perf. criteria A
EN 61000-4-3, 20 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±2 kV, perf. criteria A
Ext. input component: 24 Vin models: KY 220 µF ||TVS (SMDJ70A)
48 Vin models: KY 220 µF || TVS (SMDJ120A)
110 Vin models: KY 150 µF || TVS (SMB250A)
EN 61000-4-6, 10 Vrms, perf. criteria A
Continuous: EN 61000-4-8, 100 A/m, perf. criteria A
General Specifications
Relative Humidity
Temperature Ranges
Power Derating
Cooling System
Remote Control
95% max. (non condensing)
–40°C to +80°C
+100°C max.
–55°C to +125°C
2.5 %/K above 60°C
- Operating Temperature
- Case Temperature
- Storage Temperature
- High Temperature
- Voltage Controlled Remote
- Off Idle Input Current
Altitude During Operation
Switching Frequency
Insulation System
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Reliability
Washing Process
Environment
- Input to Output, 60 s
- Input to Case, 60 s
- Input to Output, 500 VDC
- Input to Output, 100 kHz, 1 V
- Calculated MTBF
- Vibration
- Mechanical Shock
- Thermal Shock
- Flammability
See application note: www.tracopower.com/overview/tmr6wir
Natural convection (20 LFM)
On: 0 to 0.5 VDC or open circuit
Off: 3 to 12 VDC
Refers to 'Remote' and '-Vin' Pin
2.5 mA typ.
5'000 m max.
270 - 330 kHz (PWM) (110 Vin model)
520 - 640 kHz (PWM) (other input models)
Functional Insulation
3'000 VDC
1'500 VDC
1'000 MΩ min.
100 pF max.
2'950'000 h (MIL-HDBK-217F, ground benign)
According to Cleaning Guideline
www.tracopower.com/info/cleaning.pdf
MIL-STD-810F
EN 61373
MIL-STD-810F
EN 61373
MIL-STD-810F
EN 45545-2
www.tracopower.com/info/en45545-declaration.pdf
Housing Material
Potting Material
Pin Material
Copper
Silicone (UL 94 V-0 rated)
Copper
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
September 28, 2023
Page 3 / 4
TMR 6WIR Series, 6 Watt
Pin Foundation Plating
Pin Surface Plating
Housing Type
Mounting Type
Connection Type
Footprint Type
Soldering Profile
Weight
Nickel (1 - 2 µm)
Tin (3 - 5 µm), matte
Metal Case
PCB Mount
THD (Through-Hole Device)
SIP8
Lead-Free Wave Soldering
265°C / 10 s max.
5.9 g
Environmental Compliance - REACH Declaration
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
- RoHS Declaration
www.tracopower.com/info/rohs-declaration.pdf
- SCIP Reference Number
Exemptions: 7a, 7c-I
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).)
3a804e11-6b21-4fc8-b610-94217363ca4a
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/tmr6wir
Outline Dimensions
11.2 (0.44)
Case pins should not be
connected to any circuit
0.6 (0.02)
3.5
4.1
.
(0.16)
(0.14)
2.5 (0.10)
t = 0.3 (0.012)
1.0 (0.04)
2.0 2 × 2.54
(0.08)
(2 × 0.1)
7.62
2 × 2.54
(0.3)
(2 × 0.1)
Dimensions in mm (inch)
Tolerances: x.x
x.xx
Pin pitch Tolerance
Pin dimension tolerance
21.8 (0.86)
Pinout
Pin
Single Output
Dual Output
1
–Vin (GND)
–Vin (GND)
2
+Vin (Vcc)
+Vin (Vcc)
3
Remote
Remote
6
+Vout
+Vout
7
–Vout
Common
8
NC
–Vout
9, 10
Case
NC: Not connected
Case
±0.5 (±0.02)
±0.25 (±0.01)
±0.25 (±0.01)
±0.1 (±0.004)
3
6
7
10
8
9.6 (0.38)
2
3.3
bottom view
1
(0.13)
9
0.25 (0.01)
10.6 (0.42)
1.0 (0.04)
0.5 (0.02)
© Copyright 2023 Traco Electronic AG
Specifications can be changed without notice.
www.tracopower.com
Rev. September 28, 2023
Page 4 / 4
很抱歉,暂时无法提供与“TMR 6-7215WIR”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+259.51535
- 2+245.60889